For the purpose of decreasing Infrasound Pressure occurred by blasting, New Model of Sound Screen is investigated.
This Sound Screen is composed by Roll Layer of Air Capsule Sheet made from polyethylene. Slurry explosive of 50 g
charged in Ballistic Chamber is initiated toward small size tunnel (1.6 m Dia. x 6.6 m Length) and above Screen is
set with it's opposite site. After blasting, it is measured that sound pressure level is decreases about 20 dB at
16 Hz center frequency behind 10 m remote of the Screen. To confirm this effect, the following experiment is carried
out by Acoustic Method.
This Screen is set for the partition between Reverberation Room and Anechoic Room.
By putting out Infrasound Frequency restricted 5 - 50 Hz range by loud speaker, it is also confirmed that Sound
Pressure Level decreases about 11 - 14 dB behind 50 cm point from the partition in Anechoic Room.
随道発破で騒音公害の対象となる20ヘルツ以下の超低周波音の低減化を日的とし, 直径10mmØのポリエチレン製エアーキャップシートを強固に巻きつけ, その円柱状ロールを遮音構造体とし, 音波進行の直角方向に対して直径の異なる円柱の単層体および複層体を各々設置し爆発音の遮音効果を測定した。 白砲内で起爆された含水爆発50 gの爆発音を小型坑道(径1.6m,長さ6.6m)を通し他端に設置された遮音構造体から10 m地点での16 ヘルツ周波数音圧レベルは, 遮音体無設置に対し約20dBの低減効果が認められた。 一万, 125 Hzから2 kHzの周波数領域では10 dB前後の低減化効果であった。この効果を確認するため, 残響室 - 無響室間の遮音壁をこの遮音構造体を用い, 各周波数毎の正確な音圧レベル測定をおこなった。 その結果も中心波長12.5 Hzの超低周波域において, 単層および複層共に, 無響室内の遮音体背後50 cmにおいて11-14 dBの低減化効果が確認された。 一方, 複数個ノズルから水シャワーを放出し, 発破音の遮音効果を同様に測定したが, 16-8 Kオクターブバンド中心周波数帯のいずれにおいてもその低減化効果は認められなかった。