The degradation of red water from TNT waste water was studied. Three methods were employed in this study: Fenton oxidation; Photo-Fenton oxidation, and Fenton oxidation with TiO2 photo-catalyst. Red water was decolorized by Fenton oxidation within 2 - 3 hours. The reaction rate for Fenton oxidation with TiO2 photo-catalyst > Fenton oxidation under UV radiation > Fenton oxidation.
Organic nitrogen (nitro group) was essentially mineralized to nitrate ion and ammonium ion. The nitrate ion concentration was 2.1 times greater than the ammonium ion concentration for the photo Fenton oxidation method, and 2.3 times greater than the Fenton oxidation with TiO2 photo-catalysis method. For the Fenton oxidation method, UV radiation appeared to be effective. This suggests that the reduction Fe3+→Fe2+ occurs to reproduce Fe2+ ion under radiation.
TNT製造過程で排出される廃液である赤水の処理について検討を行った。フェントン試薬を使うことにより2〜3時間で廃液の脱色が可能であった。フェントン,光フェントン,TiO2光触媒とフェントンの組み合わせの3種類の方法で処理効果を比較したところ,フェントン<光フェントン<TiO2光触媒とフェントンの組み合わせ,の順になった。
有機体窒素はほとんど硝酸イオンおよびアンモニウムイオンなどの無機体窒素に変化した。硝酸イオンはアンモニウムイオンに比べて光フェントン法で約2.1倍,TiO2光触媒とフェントンの組み合わせ法で約2.3倍ほど大きかった。また,フェントン試薬を使うときUVの照射は廃液処理に有効であることが確認できた。これは,UV光照射により3価の鉄イオンが2価の鉄イオンに再生されることによると考えられる。)
Red water, Degradation, TiO2 photo-catalyst, Fenton, Photo-Fenton
* Selected papers presented at the 2nd International Symposium on Energetic Materials and their Applications (ISEM 2005).