When an accidental explosion in a surface magazine is happened, the three primary events : air-blast, ground shock and debris, may be produced. To protect surface structures and/or human life from these events, the magazine can be constructed in a subsurface. However, the safety distances and design criteria for a subsurface magazine have not been defined yet. In a series of explosion tests, this study is to examine the effects of overburden and charge mass-to-structure volume ratio on the blast pressure resulting from an accidental explosion in a subsurface magazine. In tests, the airblast pressure propagated along the ground surface was measured by the blast pressure sensors. From the small-scale test, it has been found that the blast pressure from a subsurface magazine increases with the increase of charge mass-to -structure volume ratio. Furthermore, the value of peak pressure has been formulated as a function of the charge massto- structure volume ratio.
火薬庫に貯蔵されている大量の火薬類が爆発した場合,爆風や火薬庫の破壊に伴う飛散物および地盤振動によって火 薬庫周辺に重大な被害を与えることが考えられる。そこで,周辺地域への爆発の影響が少ない火薬庫形式として,地下 に建設する地下式火薬庫が考えられる。わが国では,これまで地下式火薬庫が建設された例がなく,設置に係る技術基 準や保安距離が現行法令に規定されていない。加えて,地下式火薬庫の建設技術や爆発事故による地表への影響に関す る研究は極めて少ない。本報では,地下式火薬庫の建設に資する技術的資料を得ることを目的として,土かぶり厚さと 薬量−容積比(薬室の単位容積あたりの薬量)を変化させたコンクリート構造の模型地下式火薬庫内において爆薬を爆 発させ,地表に吹き出す爆風圧について検討を行った。その結果,薬量−容積比が大きいほど地下式火薬庫から地表に 吹き出す爆風圧が大きくなる傾向が認められた。さらに,薬量−容積比の影響を考慮した庫外爆風圧の評価式を提案し た。
Subsurface magazine, blast pressure, scaled distance, overburden, charge mass-to-structure volume ratio.